Технические характеристики коммутатора Cisco DS-C9148T-24IK9:

Protocols

  • Fibre Channel standards
  • FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
  • FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
  • FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
  • FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
  • FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
  • FC-PI, Revision 13 (ANSI INCITS 352-2002)
  • FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
  • FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
  • FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
  • FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
  • FC-PI-6 (ANSI INCITS 512-2015)
  • FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
  • FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
  • FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
  • FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
  • FC-FS-4
  • FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
  • FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
  • FC-LS-3, Includes revision 3.53
  • FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
  • FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
  • FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
  • FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
  • FC-SW-6
  • FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
  • FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
  • FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
  • FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
  • FC-GS-7, Includes revision 10.8
  • FCP, Revision 12 (ANSI INCITS 269-1996)
  • FCP-2, Revision 8 (ANSI INCITS 350-2003)
  • FCP-3, Revision 4 (ANSI INCITS 416-2006)
  • FCP-4, Revision 2b (ANSI INCITS 481-2011)
  • FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
  • FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
  • FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
  • FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
  • FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
  • FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
  • FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
  • FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
  • FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
  • FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
  • FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
  • FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
  • FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
  • FAIS, Revision 1.03 (ANSI INCITS 432-2007)
  • FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
  • FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
  • FC-FLA, Revision 2.7 (INCITS TR-20-1998)
  • FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
  • FC-Tape, Revision 1.17 (INCITS TR-24-1999)
  • FC-MI, Revision 1.92 (INCITS TR-30-2002)
  • FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
  • FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
  • FC-DA, Revision 3.1 (INCITS TR-36-2004)
  • FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
  • FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
  • Fibre Channel classes of service: Class 2, Class 3, and Class F
  • Fibre Channel standard port types: E, F, and B
  • Fibre Channel enhanced port types: SD, ST, and TE
  • FC-NVMe
  • In-band management using IP over Fibre Channel (RFC 2625)
  • IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
  • Extensive IETF-standards-based TCP/IP, Simple Network Management Protocol Version 3 (SNMPv3), and Remote Monitoring (RMON) MIBs

Fibre Channel ports

  • Fixed-switch form factor with 48 SFP+ ports base
  • Entry-level 24-port preactivated base model with flexibility to turn on any 24 ports
  • Incremental ports

-          8-ports upgrade license offers the option of upgrading to 32, 40, and 48 ports

Security

  • VSAN fabric isolation
  • Intelligent packet inspection at port level
  • Hardware zoning by Access Control Lists (ACLs)
  • Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication
  • FC-SP host-to-switch authentication
  • Role-based access control (RBAC) using RADIUS, TACACS+, or Lightweight Directory Access Protocol (LDAP) authentication, authorization, and accounting (AAA) functions
  • Secure FTP (SFTP)
  • Secure Shell Protocol Version 2 (SSHv2)
  • Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
  • Control-plane security
  • Cisco TrustSec® payload encryption
  • Secure Boot and Anti-counterfeit technology

Performance

  • Port speed: 4-, 8-, 16-, and 32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
  • Aggregate bandwidth of 1.5-Tbps end-to-end full duplex
  • Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
  • Port groups: 3 port groups of 16 ports each
  • Port channel: Up to 16 load-balanced physical links grouped in one port channel

Diagnostics

  • Power-On-Self-Test (POST) diagnostics
  • Online Health Management System (OHMS) diagnostics
  • Internal loopbacks
  • SPAN
  • Fibre Channel traceroute
  • Fibre Channel ping
  • Fibre Channel debug
  • Cisco Fabric Analyzer
  • Syslog
  • Port-level statistics
  • Link diagnostics (E-port and F-port links)
  • Read Diagnostic Parameter

Serviceability

  • Configuration file management
  • Call Home
  • Port beaconing
  • Link cable beacon
  • System LEDs
  • SNMP traps for alerts

Reliability and availability

  • Cisco In-Service Software Upgrade (ISSU)
  • Hot-swappable, dual redundant power supplies
  • Hot-swappable fan tray with switch integrated temperature and power management
  • Hot-swappable SFP+ optics
  • Stateful process restart
  • Any port configuration for port channels
  • Fabric-based multipathing
  • Per-VSAN fabric services
  • Port tracking
  • Virtual Router Redundancy Protocol (VRRP) for management IP interface
  • FEC with HBA ports
  • Buffer-to-buffer state change notification with HBA ports

Network management

  • Management access through 2 out-of-band Ethernet ports

-          mgmt0: 10/100/1000BASE-T port

-          mgmt1: 1/10G SFP+ port #

  • RS-232 serial console port
  • USB power-on auto-provision port
  • Access protocols
  • Command-Line Interface (CLI) using the console and Ethernet port
  • SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
  • Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
  • NX-API for REST
  • full access through HTTPS REST
    • Distributed device alias service
    • Network security
    • Per-VSAN RBAC using LDAP, RADIUS, and TACACS+-based AAA functions
    • Simple File Transfer Protocol (SFTP)
    • SSHv2 implementing AES
    • SNMPv3 implementing AES
    • Cisco Data Center Network Manager (DCNM)

Programming interfaces

  • Scriptable CLI
  • Cisco Prime® DCNM web services API
  • NX-API RESTful interfaces
  • Onboard Python interpreter
  • Cisco Embedded Event Manager (EEM)
  • Cisco NX-OS Software scheduler

Physical dimensions 
(H x W x D) and weight

  • 1 Rack Unit (1RU) (1.72 x 17.3 x 22.3 in. [4.37 x 43/9 x 56.6 cm]) excluding Power Supply Unit (PSU) and fan-tray handles
  • 16.7 lb. (8.5 kg)

Power

  • 80 Plus Platinum certified power supplies
  • Power supply options

-          650W AC in base model, port-side exhaust variant (2 per switch)

-          650W AC in base model, port-side intake variant (2 per switch)

  • Power cord

-          IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 later in this document for power cords specific to regions)

  • AC input: 100 to 240 VAC (10% range)
  • Frequency: 50 to 60 Hz (nominal)
  • Typical power consumption

-          217W for Idle 48-Port switch without optics modules

-          251W for 48-Port switch with 24 32G SW optics modules under typical conditions

-          297W for 48-Port switch with 48 32G SW optics modules under typical conditions

  • Airflow

-          Back to front (toward ports) using port-side exhaust fans

-          Front to back (inward from ports) using port-side intake fans

-          50 Cubic Feet per Minute (CFM) through system fan assembly at 77°F (25°C)

-          100 CFM maximum

Temperature range

  • Temperature, ambient operating:

-          32 to 104°F (0 to 40°C) with port-side exhaust and intake airflow variants

  • Temperature, ambient nonoperating and storage: –40 to 158°F (–40 to 70°C)
  • Relative humidity, ambient (noncondensing) operating: 10 to 90%
  • Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
  • Altitude, operating: –197 to 6500 ft (–60 to 2000m)

Approvals and compliance

  • Safety compliance
  • CE Marking
  • UL 60950
  • CAN/CSA-C22.2 No. 60950
  • EN 60950
  • IEC 60950
  • TS 001
  • AS/NZS 3260
  • IEC60825
  • EN60825
  • 21 CFR 1040
  • EMC compliance
  • FCC Part 15 (CFR 47) Class A
  • ICES-003 Class A
  • EN 55022 Class A
  • CISPR 22 Class A
  • AS/NZS 3548 Class A
  • VCCI Class A
  • EN 55024
  • EN 50082-1
  • EN 61000-6-1
  • EN 61000-3-2
  • EN 61000-3-3

Fabric services

  • Name server
  • Registered State Change Notification (RSCN)
  • Login services
  • Fabric Configuration Server (FCS)
  • Broadcast
  • In-order delivery

Advanced functions

  • VSAN
  • IVR
  • Port Channel with multipath load balancing
  • Flow- and zone-based QoS
Для цього товару немає додаткових зображень