Protocols
|
-
Fibre Channel standards
-
FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
-
FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
-
FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
-
FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
-
FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
-
FC-PI, Revision 13 (ANSI INCITS 352-2002)
-
FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
-
FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
-
FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
-
FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
-
FC-PI-6 (ANSI INCITS 512-2015)
-
FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
-
FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
-
FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
-
FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
-
FC-FS-4
-
FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
-
FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
-
FC-LS-3, Includes revision 3.53
-
FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
-
FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
-
FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
-
FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
-
FC-SW-6
-
FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
-
FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
-
FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
-
FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
-
FC-GS-7, Includes revision 10.8
-
FCP, Revision 12 (ANSI INCITS 269-1996)
-
FCP-2, Revision 8 (ANSI INCITS 350-2003)
-
FCP-3, Revision 4 (ANSI INCITS 416-2006)
-
FCP-4, Revision 2b (ANSI INCITS 481-2011)
-
FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
-
FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
-
FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
-
FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
-
FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
-
FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
-
FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
-
FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
-
FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
-
FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
-
FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
-
FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
-
FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
-
FAIS, Revision 1.03 (ANSI INCITS 432-2007)
-
FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
-
FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
-
FC-FLA, Revision 2.7 (INCITS TR-20-1998)
-
FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
-
FC-Tape, Revision 1.17 (INCITS TR-24-1999)
-
FC-MI, Revision 1.92 (INCITS TR-30-2002)
-
FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
-
FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
-
FC-DA, Revision 3.1 (INCITS TR-36-2004)
-
FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
-
FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
-
Fibre Channel classes of service: Class 2, Class 3, Class F
-
Fibre Channel standard port types: E, F, and B
-
Fibre Channel розширений port типи: SD, ST, and TE
-
NVMe/FC
-
In-band management using IP over Fibre Channel (RFC 2625)
-
IPv6, IPv4, і Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
-
Extensive IETF-standards-based TCP/IP, SNMPv3, та Remote Monitoring (RMON) MIBs
|
Fibre Channel ports
|
-
Fixed switch form factor with 16 SFP+ порти base and one 16 SFP+ port expansion slot
-
Вхідний рівень 8-розрядний перехідний базовий модель з функціональністю до торну на 8 портів
-
Incremental ports
- На 8-розрядному модулі моделі, з 8-портовим налаштуванням license to activate up to 16 ports on the base switch
- На 8-розрядному модулі моделі, з 16-розширювальним модулем до 24 функцій
- На 16-першому налаштуванні, з 16-портом розширення module до 32 функцій
- На 24-порт configuration, з 8-Port On-Demand Activation license to activate up to 32 ports
|
Security
|
-
VSAN fabric isolation
-
Intelligent packet inspection @ port level
-
Hardware zoning by Access Control Lists (ACLs)
-
FC-SP switch-to-switch authentication
-
FC-SP host-to-switch authentication
-
RBAC використовуючи RADIUS, TACACS+ або LDAP Authentication, Authorization, and Accounting (AAA) функцій
-
Secure FTP (SFTP)
-
Secure Shell Version 2 (SSHv2)
-
Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
-
Control-plane security
-
Cisco TrustSec payload encryption
-
Secure Boot and Anti-counterfeit технології
|
Performance
|
-
Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps dedicated bandwidth per port
-
Aggregate bandwidth of 1024 Gbps end-to-end full duplex
-
Buffer credits: До 8300 для групи 16 портів, з більш ніж 500 buffer credits per port and maximum of 8270 buffer credits for single port in the group
-
Port channel: До 16 load-balanced physical links grouped in one port channel
|
Diagnostics
|
-
Power-on-Self-Test (POST) diagnostics
-
Online Health Management System (OHMS) diagnostics
-
Internal loopbacks
-
SPAN
-
Fibre Channel traceroute
-
Fibre Channel ping
-
Fibre Channel debug
-
Cisco Fabric Analyzer
-
Syslog
-
Port-level statistics
-
Link Diagnostics ( ISL Diagnostics and HBA Diagnostics)
-
Read Diagnostic Parameter
|
Serviceability
|
-
Configuration file management
-
Call Home
-
Port beaconing
-
Link Cable Beacon
-
System LEDs
-
SNMP traps for alerts
|
Reliability and availability
|
-
Cisco In-Service Software Upgrade (ISSU)
-
Hot-swappable, dual redundant power supplies
-
Hot-swappable fan tray with switch integrated temperature and power management
-
Hot-swappable SFP+ optics
-
Stateful process restart
-
Any port configuration for port channels
-
Fabric-based multi pathing
-
Per-VSAN fabric services
-
Port tracking
-
VRRP for management IP interface
|
Network management
|
-
Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports
- mgmt0: 10/100/1000BASE-T port
- mgmt1: 10/100/1000BASE-T port
-
RS-232 serial console port
-
USB power-on auto-provision port
-
Access protocols
-
Command-Line Interface (CLI), використовуючи console and Ethernet port
-
SNMPv3 використовуючи Ethernet port and in-band IP over Fibre Channel access
-
Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
-
NX-API для повного доступу до HTTPS
-
Distributed device alias service
-
Network security
-
Per-VSAN Role-Based Access Control (RBAC) використовуючи LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) функцій
-
SFTP
-
SSHv2 implementing AES
-
SNMPv3 implementing AES
-
Cisco Data Center Network Manager
|
Programming interfaces
|
-
Scriptable CLI
-
Cisco Prime DCNM Web Services API
-
NX-API restful interfaces
-
On-board Python interpreter
-
Cisco Embedded Event Manager
-
Cisco NX-OS Software scheduler
|
Physical dimensions (HxWxD) and weight
|
-
1RU (1.72 inches x 17.3 inches x 20.11 inches) excluding Power Supply Unit (PSU) and fan tray handles
-
9.1 kg with 16 activated ports
-
9.82 kg with all 32 activated ports
|
Power
|
-
80 Plus Platinum certified power supplies
-
Power supply options
- 650W AC в базовому model, port-side exhaust variant (up to 2 per switch)
- 650W AC в базовому model, port-side intake variant (up to 2 per switch)
- IEC60320 C14 plug на 650W потужність підключення до захищеного C15 блоку під'єднання (check Table 6 for power cords specific to regions)
-
AC input: 100 to 240V AC (10% range)
-
Frequency: 50 to 60 Hz (nominal)
-
Typical power consumption
- 72W for idle base switch with 16 ports activated without SFPs
- 43W for idle expansion module with 16 ports activated without SFPs
- 80W for 8 ports activated with 32G SFPs with traffic at 25°C
- Back to front (toward ports) використовуючи port-side exhaust fans
- Front back (inward from ports) використовуючи port-side intake fans
- 50 Cubic Feet per Minute (CFM) через систему fan assembly at 25°C
- 100 CFM maximum
|
Temperature range
|
-
Temperature, ambient operating:
- 32 to 104°F (0 to 45°C) with port-side exhaust airflow variant
- 32 to 131°F (0 to 55°C) with port-side intake airflow variant
-
Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C)
-
Relative humidity, ambient (noncondensing) operating: 10 to 90%
-
Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
-
Altitude, operating: -197 to 6500 ft (-60 to 2000m)
|
Approvals and compliance
|
-
Safety compliance
-
CE Marking
-
UL 60950
-
CAN/CSA-C22.2 No. 60950
-
EN 60950
-
IEC 60950
-
TS 001
-
AS/NZS 3260
-
IEC60825
-
EN60825
-
21 CFR 1040
-
EMC compliance
-
FCC Part 15 (CFR 47) Class A
-
ICES-003 Class A
-
EN 55022 Class A
-
CISPR 22 Class A
-
AS/NZS 3548 Class A
-
VCCI Class A
-
EN 55024
-
EN 50082-1
-
EN 61000-6-1
-
EN 61000-3-2
-
EN 61000-3-3
|
Fabric services
|
-
Name server
-
Registered State Change Notification (RSCN)
-
Login services
-
Fabric Configuration Server (FCS)
-
Broadcast
-
In-order delivery
|
Advanced functions
|
-
VSAN
-
IVR
-
Port channel with multipath load balancing
-
Flow-based and zone-based QoS
|