Прийом замовлень:
9:00 - 19:00 Пн-Пт
Замовлення по телефонам:
+38 (044) 49-400-85
+38 (063) 49-400-85
+38 (050) 87-165-11
skype
[email protected]
 
Кошик порожній
 

Коммутатор Cisco DS-C9250I-K9

Коммутатор Cisco DS-C9250I-K9
Натисніть, щоб збільшити
GPL $67,234.00
Цена уточняйте
Артикул: DS-C9250I-K9
Виробник: Cisco

Технические характеристики коммутатора Cisco DS-C9250I-K9:

Product compatibility

Cisco MDS 9000 Family

Software compatibility

Cisco MDS 9000 NX-OS Release 6.2(2) or later

Cisco MDS 9000 NX-OS Release 6.2(2) or later for Cisco Prime DCNM support

Protocols

Fibre Channel standards

  • FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
  • FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
  • FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
  • FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
  • FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
  • FC-PI, Revision 13 (ANSI INCITS 352-2002)
  • FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
  • FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
  • FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
  • FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
  • FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
  • FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
  • FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
  • FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
  • FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
  • FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
  • FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
  • FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
  • FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
  • FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
  • FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
  • FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
  • FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
  • FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
  • FCP, Revision 12 (ANSI INCITS 269-1996)
  • FCP-2, Revision 8 (ANSI INCITS 350-2003)
  • FCP-3, Revision 4 (ANSI INCITS 416-2006)
  • FCP-4, Revision 2b (ANSI INCITS 481-2011)
  • FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
  • FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
  • FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
  • FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
  • FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
  • FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
  • FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
  • FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
  • FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
  • FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
  • FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
  • FAIS, Revision 1.03 (ANSI INCITS 432-2007)
  • FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
  • FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
  • FC-FLA, Revision 2.7 (INCITS TR-20-1998)
  • FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
  • FC-Tape, Revision 1.17 (INCITS TR-24-1999)
  • FC-MI, Revision 1.92 (INCITS TR-30-2002)
  • FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
  • FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
  • FC-DA, Revision 3.1 (INCITS TR-36-2004)
  • FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
  • FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
  • FC-AL, Revision 4.5 (ANSI/INCITS 272-1996) #
  • FC-AL-2, Revision 7.0 (ANSI/INCITS 332-1999) #
  • FC-AL-2, Amendment 1 (ANSI/INCITS 332-1999/AM1-2003) #
  • FC-AL-2, Amendment 2 (ANSI/INCITS 332-1999/AM2-2006) #

Fibre Channel classes of service: Class 2, Class 3, and Class F

Fibre Channel standard port types: E, F, FL, and B

Fibre Channel enhanced port types: SD, ST, and TE

IP over Fibre Channel (RFC 2625)

Protocols (continued)

IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)

Extensive IETF-standards based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs

IP standards

  • RFC 791 IPv4
  • RFC 793 and 1323 TCP
  • RFC 894 IP/Ethernet
  • RFC 1041 IP/802
  • RFC 792, 950, and 1256 ICMP
  • RFC 1323 TCP performance enhancements
  • RFC 2338 VRRP
  • RFC 2460 and 4291 IPv6
  • RFC 2463 and 4443 ICMPv6
  • RFC 2461 and 2462 IPv6 neighbor discovery and stateless autoconfiguration
  • RFC 2464 IPv6/Ethernet
  • RFC 3270 and 3980 iSCSI
  • RFC 3643 and 3821 FCIP

Ethernet standards

  • IEEE Std 802.3-2005 Ethernet
  • IEEE Std 802.1Q-2005 VLAN
  • IPsec
  • RFC 2401 and 4301 security architecture for IP
  • RFC 2403 and 2404 HMAC
  • RFC 2405, 2406, 2451, and 4303 IP ESP
  • RFC 2407 and 2408 ISAKMP
  • RFC 2412 OAKLEY Key Determination Protocol
  • RFC 3566, 3602, and 3686 AES

Internet Key Exchange (IKE)

  • RFC 2409 IKEv1
  • RFC 4306 IKEv2

Cards, ports, and slots

Fixed configuration with 40 ports of 16-Gbps Fibre Channel and 10 ports of 10-Gigabit Ethernet

Fabric services

Name server

Internet Storage Name Server (iSNS)

Registered State Change Notification (RSCN)

Login services

Fabric Configuration Server (FCS)

Public loop

Broadcast

In-order delivery

Advanced functions

VSAN

IVR

PortChannel with multipath load balancing

Flow-based and zone-based QoS

FCIP tape read and write acceleration

FICON over FCIP tape read and write acceleration (pipelining)

FICON XRC (z/OS Global Mirror) acceleration

Diagnostics and troubleshooting tools

POST diagnostics

Cisco Generic Online Diagnostics (GOLD)

Internal port loopbacks

SPAN and Remote SPAN (RSPAN)

Fibre Channel traceroute

Fibre Channel ping

Fibre Channel debug

Cisco Fabric Analyzer

Syslog

Online system health

Port-level statistics

Real-Time Protocol (RTP) debug

Network security

VSANs

ACLs

Per-VSAN RBAC

Fibre Channel zoning

N-port Worldwide Name (WWN)

N-port FC-ID

Fx-port WWN

Fx-port WWN and interface index

Fx-port domain ID and interface index

Fx-port domain ID and port number

iSCSI zoning

iSCSI name

IP address

FC-SP

DH-CHAP switch-to-switch authentication

DH-CHAP host-to-switch authentication

Port security and fabric binding

IPsec for FCIP and iSCSI

IKEv1 and IKEv2

Management access

SSHv2 implementing AES

SNMPv3 implementing AES

SFTP

FICON

FC-SB-3 compliant

Cascaded FICON fabrics

Intermix of FICON and Fibre Channel Protocol traffic

CUP management interface

Serviceability

Configuration file management

ISSU for Fibre Channel interfaces

Cisco Call Home

Power-management LEDs

Port beaconing

System LED

SNMP traps for alerts

Network boot

Performance

Port speed: 2/4/8/16-Gbps autosensing, optionally configurable

Buffer credits: 64 per port (shared-mode ports) and up to 253 on an individual port (dedicated-mode ports)

Ports per chassis: 40 ports of 16-Gbps Fibre Channel, 8 ports of 10-Gigabit Ethernet FCoE and 2 ports of 1/10-Gigabit Ethernet

Ports per rack: Up to 1050

PortChannel: Up to 16 physical links

FCIP tunnels: Up to 6 per port

Reliability and availability

ISSU

Hot-swappable, 2+1 redundant power supplies

Hot-swappable fan tray with integrated temperature and power management

Hot-swappable SFP+ optics

Passive backplane

Stateful process restart

Any port configuration for PortChannels

Fabric-based multipathing

Per-VSAN fabric services

Port tracking

VRRP for management and FCIP or iSCSI connections

Online diagnostics

Network management

Access methods

  • Out-of-band 10/100 Gigabit Ethernet port
  • RS-232 serial console port
  • In-band IP over Fibre Channel
  • In-band FICON CUP over Fibre Channel
  • USB (Software support to be enabled in a future release)

Access protocols

  • CLI using the console and Ethernet ports
  • SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
  • Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
  • FICON CUP

Distributed device alias service

Network security

  • Per-VSAN RBAC using RADIUS and TACACS+-based authentication, authorization, and accounting (AAA) functions
  • SFTP
  • SSHv2 implementing AES
  • SNMPv3 implementing AES

Management applications

  • Cisco MDS 9000 Family CLI
  • Cisco Prime DCNM
  • Cisco Device Manager

Programming interfaces

Scriptable CLI

Cisco Prime DCNM web services API

Cisco Device Manager GUI

Environmental

Temperature, ambient operating: 32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage: 40 to 158°F (-40 to 70°C)

Relative humidity, ambient (noncondensing) operating: 10 to 90%

Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%

Altitude, operating: -197 to 6500 ft (-60 to 2000m)

Physical dimensions

Dimensions (H x W x D): 3.84 x 17.22 x 21.4 in. (9.75 x 43.74 x 54.36 cm), 2RUs; all units rack mountable in standard 19-inch Electronic Industries Alliance [EIA] rack)

Weight of fully configured chassis: 22.4 lb (10.2 kg)

Power and cooling

Power supply: 300W AC

Power cord: Notched C15 socket connector connecting to C16 plug on power supply

AC input characteristics

100 to 240V AC (10% range)

50 to 60 Hz (nominal)

Airflow (front to back)

200 linear feet per minute (LFM) through system fan assembly

Approvals and compliance

Safety compliance

CE Marking

UL 60950

CAN/CSA-C22.2 No. 60950

EN 60950

IEC 60950

TS 001

AS/NZS 3260

IEC60825

EN60825

21 CFR 1040

EMC compliance

FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55022 Class A

CISPR 22 Class A

AS/NZS 3548 Class A

VCCI Class A

EN 55024

EN 50082-1

EN 61000-6-1

EN 61000-3-2

EN 61000-3-3

Для цього товару немає додаткових зображень